U7698E Flame Detector
22
Part 334614E
E 2002 Nordson Corporation
Manual 34-49
Installing the New Sensor and Electronics Modules
1. Set the configuration switches. See Figure 5 for settings.
2. See Figure 8. Plug the electronics module (10) DIN connector into the
socket on the connector board in the upper housing (8). Secure in place
by tightening the mounting screws.
NOTE: Apply molybdenum disulfide grease to the lower housing and
sensor housing threads to prevent galling or binding.
3. Screw the lower housing (11) into the upper housing.
4. Connect the harness connector (7) to the sensor module (6) and place
the sensor into the upper housing, making sure it is aligned properly.
5. Install the sensor housing (5) over the sensor. Screw the sensor
housing onto the upper housing.
6. If removed, install the air shield (3) onto the sensor housing. Tighten the
socket-head screws (4) to secure it to the sensor housing.
7. Connect the air tubing (1) to the air fitting (2).
1400500A
3
4
1
5
6
7
8
9
10
11
2
ATTENTION
Figure 8 Sensor and Electronics Module Replacement
1. Air tubing
2. Air fitting
3. Air shield
4. Socket-head screws
5. Sensor housing
6. Sensor module
7. Harness connector
8. Upper housing
9. Terminal block
10. Electronics module
11. Lower housing